Power Supply Unit

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inside View of Power Supply Unit.


1. Microprocessor based controller provides :-
Complete control of H.F. Welder sequence.
Automatic power speed control which greatly reduces open seam tube through accurate
control of weld power at start and shut down.

2. Closed loop thyristor (SCR) power control system along with low ripple LC filter provides
step less heat control.
 

 

 

 


 

1. Oil or air colled high tension plate transformer. The transformer has high impedence so as to limit the fault current to a max of 10 x I rated.

2. Low Ripple LC Filter
 

The main power supply unit has the following components installed:

Enclosure
Free floor standing pressurised with all around access, dust and fume proof enclosure, internal forced cooling by air to water heat exchanger. Cable entry from top/bottom and water inlet-outlet from the side (near the bottom) of the enclosure.

Main Supply Breaker


Molded case circuit breaker of suitable rating is provided as standard.

1. Alphanumeric Intelligent Display for fault diagnostic information and on line welder parameters.


H. T. Contractor

Triple pole power contactor of suitable rating for disconnecting the mains supply to the equipment.

Thyristor Phase Control Unit (Automatic Voltage Regulator)

Composed of three sets of water cooled thyristor stacks, with each stack containing two back to back thyristors. By controlling the phase angle of the thyristors, the welder output can be adjusted from zero to maximum steplessly and at the same time welder output is stabilized to +/- 1% for an input voltage variation of +/-10%

Auto Speed-Power Controller (Optional)

A closed loop electronic regulator is provided to control main supply voltage in accordance with the output power requirement.

Oscillator Valve filament Supply Regulator

A single phase closed loop thyristor control voltage regulator or CVT is provided to regulate oscillator valve filament supply. The filament supply is stabilized to +/- 1.5% for an input supply variations of +/-10%. Filament voltage is gradually set by a built in ramp circuit.

Control Supply Transformer

Standard 110 Volts.

High Tension (Anode) Transformer

It steps up the thyristor controlled main AC voltage into high voltage AC to feed the high voltage rectifier. Since the transformer is located in the power supply cubical chamber, it is designed to withstand high frequency environment.

Cooling:

Water cooled by internal water-oil heat exchanger connected to distilled water circuit.
With the result little amount of heat is transmitted from the transformer tank to other components. Dry type transformer is provided as standard for North America

Impregnated windings:

Standard primary voltage - 380 Volts, 3 Phase, 50 Hz.

High Voltage Ripple Filter

Programmable Logic Controller

It is a compact and powerful PLC with real time clock and it can be easily programmed with the help of a PC.

Metering Plate

Metering plate is mounted on the door of the power supply cubical and is provided with the following meters, selector switches:-

(a) H.T. Voltmeter
(b) Anode current ammeter
(c) Filament voltmeter
(d) Grid current ammeter
(e) SCR output voltmeter with selector switch
(f) Line current ammeter with selector switch
(g) Emergency stop push button

Digital Display

Alphanumeric LCD back lit display provided with following function keys:-

(a) Distilled water pump ON/OFF push buttons
(b) Weld heat ON/OFF push button
(c) Local remote selector switch
(d) Test-run selector switch
(e) Reset push button

In addition the LCD screen displays extensive fault information

Local Cooling Connections

Copper/S.S. and carbon free rubber hose pipes to avoid corrosion of the pipe lines and contamination of distilled

water. All heat generating parts are water cooled viz. thyristor, transformer, cooling coils etc. to the inlet and outlet connections.

Standard Protections

(a) Magnetic short circuit (Provided in the main supply MCCB)
(b) Instantaneous electronic over current trip
(c) Instantaneous DC magnetic over load relay
(d) Ambient temperature thermostat
(e) Magnetic float type water flow switch
(f) Thyristor over temperature thermostat
(g) Metal oxide varistors in the incoming lines to protect thyristors from high voltage transient in the main supply
(h) "Spark Gap" to protect oscillator valve and other components
(I) earth droppers
(j) electromechanical door inter lock in high voltage compartment
(k) Input water over temperature thermostat

 

 
   
 